Collections

超声诊疗二
Sort by Default Latest Most read  
Please wait a minute...
  • Select all
    |
  • Review Articles
    LU Xiao, MA Jiaojiao, SUN Mai, ZHANG Bo
    Acta Academiae Medicinae Sinicae. 2024, 46(4): 575-580. https://doi.org/10.3881/j.issn.1000-503X.15784
    Abstract (1442) Download PDF (338) HTML (1367)   Knowledge map   Save

    Hepatic sinusoidal obstruction syndrome (HSOS),a toxic liver injury,can lead to multiple organ failure in severe cases and is even fatal.Early diagnosis is of great significance for the selection of treatment regimens and prognosis.Currently,ultrasound,as the preferred diagnostic method for liver diseases,has been recommended in expert consensus and criteria for the diagnosis of HSOS.However,there are no definitive imaging diagnostic standards.This paper summarizes the sonographic features of ultrasound and new ultrasound technologies in HSOS research.Analyzing the characteristic sonographic images from gray-scale ultrasonography,Doppler ultrasonography,ultrasound elastography,and contrast-enhanced ultrasonography at different stages of the disease enables the establishment and refining of the corresponding imaging diagnostic standards and provides effective auxiliary examination methods for the early diagnosis and differential diagnosis of HSOS.

  • Original Articles
    LI Xu, LIN Yu, CHENG Yiming, ZHAO Xiaoyu, GOU Taohua, ZHANG Yan
    Acta Academiae Medicinae Sinicae. 2024, 46(3): 370-376. https://doi.org/10.3881/j.issn.1000-503X.15894

    Objective To explore the diagnostic value of ultrasound for thyroid nodules with a spoke-wheel blood flow pattern.Methods The clinical data of the patients with thyroid nodules presenting a spoke-wheel blood flow pattern examined by ultrasound were collected,and the gray-scale ultrasound features of the nodules were recorded.The diagnostic performance of the Thyroid Imaging Reporting and Data System by American College of Radiology (ACR TI-RADS),Chinese Thyroid Imaging Reporting and Data System (C-TIRADS),and combined specific indicators for the thyroid nodules with a spoke-wheel blood flow pattern was evaluated by comparison with the pathological results,which was regarded as the gold standard.Results A total of 64 patients with thyroid nodules were finally included,including 47 patients with malignant nodules and 17 patients with benign nodules.In addition to the general ultrasound features,central scar mostly appeared in malignant nodules (χ2=5.968,P=0.015),while central coarse calcification was more common in benign nodules (χ2=10.899,P=0.001).After the combination of central scar and central gross calcification,the diagnostic performance of ACR TI-RADS and C-TIRADS was improved (both P<0.001).Conclusions When the thyroid nodule shows a spoke-wheel blood flow pattern,one should be cautious of the possibility of malignancy.Combining central scar and central coarse calcification can improve the accuracy of ultrasonic diagnosis.

  • Original Articles
    LIN Yu, LUO Yukun, LI Jie, REN Xiuyun, WANG Hongwei
    Acta Academiae Medicinae Sinicae. 2023, 45(6): 921-928. https://doi.org/10.3881/j.issn.1000-503X.15754

    Objective To explore the diagnostic efficacy of American Thyroid Association(ATA)guidelines,American College of Radiology Thyroid Imaging Report and Data System(ACR-TIRADS),and Chinese Thyroid Imaging Reporting and Data System(C-TIRADS)alone and combined with BRAFV600E mutation in atypia of undetermined significance/follicular lesion of undetermined significance(AUS/FLUS).Methods A total of 138 patients who underwent ultrasound-guided fine needle aspiration(FNA)in the Chinese PLA General Hospital from January 2020 to May 2023 were selected.The clinicopathological and ultrasound characteristics were retrospectively analyzed for each nodule.Each nodule underwent preoperative BRAFV600E mutation testing and was diagnosed according to the ATA guidelines,ACR-TIRADS,and C-TIRADS.The diagnostic efficacy of ATA guidelines,ACR-TIRADS,and C-TIRADS alone and combined with BRAFV600E mutation was assessed based on the results of histopathological diagnosis.Results The 138 AUS/FLUS thyroid nodules included 45(32.6%)benign ones and 93(67.4%)malignant ones.The patient age(t=1.444,P=0.151),gender(χ2=0.259,P=0.611),and location of nodules(χ2=2.055,P=0.358)had no statistical significance for the differentiation between benign and malignant nodules,while nodule size(Z=2.500,P=0.012),echo(χ2=14.693,P<0.001),composition(χ2=17.075,P<0.001),aspect ratio ≥1(χ2=9.477,P=0.002),and microcalcification(χ2=6.892,P=0.009)were of significance for the differentiation.When applied alone,BRAFV600E mutation showed high specificity(95.56%)and positive predictive value(95.65%).Among the three ultrasound grading systems,ACR-TIRADS had the highest sensitivity(χ2=37.923,P<0.001;χ2=40.462,P<0.001)and accuracy(χ2=81.595,P<0.001;χ2=76.912,P<0.001),while C-TIRADS had the highest specificity(χ2=11.746,P<0.001;χ2=21.235,P<0.001).However,the three systems showed no statistically significant difference in the diagnostic efficiency when applied alone(Z=1.177,P=0.239;Z=0.213,P=0.831;Z=1.016,P=0.310).The combination of BRAFV600E mutation with ACR-TIRADS or C-TIRADS improved the diagnostic efficacy of BRAFV600E mutation in distinguishing the benign and malignant AUS/FLUS nodules(Z=2.107,P=0.035;Z=2.752,P=0.006).The combination of ATA guidelines with BRAFV600E mutation increased the diagnostic accuracy of BRAFV600E mutation(χ2=20.679,P<0.001),while it had no statistically significant difference in distinguishing the benign and malignant AUS/FLUS nodules(Z=1.321,P=0.186).The combination of ATA guidelines,ACR-TIRADS,or C-TIRADS with BRAFV600E mutation improved the diagnostic efficacy of ultrasound grading systems for AUS/FLUS nodules(Z=2.770,P=0.006;Z=2.770,P=0.006;Z=2.890,P=0.004).Specifically,ACR-TIRADS combined with BRAFV600E mutation showed the highest sensitivity(χ2=4.712,P=0.030;χ2=4.712,P=0.030),while C-TIRADS combined with BRAFV600E mutation showed the highest accuracy(χ2=77.627,P<0.001;χ2=85.827,P<0.001).However,there were no statistically significant differences in diagnostic performance between the combinations(Z=1.276,P=0.202;Z=0.808,P=0.419;Z=1.615,P=0.106).Conclusion ATA guidelines,ACR-TIRADS,and C-TIRADS combined with BRAFV600E mutation can improve the diagnostic efficacy of BRAFV600E mutation or ultrasound grading system alone in AUS/FLUS nodules,which can facilitate the further management and treatment of such patients.

  • Original Articles
    LI Yiming, YAN Lin, XIAO Jing, ZHANG Mingbo, LUO Yukun
    Acta Academiae Medicinae Sinicae. 2023, 45(5): 803-808. https://doi.org/10.3881/j.issn.1000-503X.15504

    Objective To investigate the effect of calcification on the ultrasound-guided radiofrequency ablation(RFA)of papillary thyroid carcinoma(PTC).Methods We retrospectively analyzed the preoperative and follow-up data of 164 patients(182 nodules)with PTC treated by percutaneous ultrasound-guided RFA in the First Medical Center of Chinese PLA General Hospital from January 1,2018 to December 31,2021.The tumor status 12 months after RFA was taken as the endpoint event.The univariate Logistic regression analysis was employed to predict the influencing factors of incomplete ablation.The factors were then included in the multivariate Logistic regression analysis for prediction of the independent risk factors of incomplete ablation.Results The maximum nodule diameter(OR=1.16,95%CI=1.04-1.29,P=0.009)and calcification ratio >2/3(OR=19.27,95%CI=4.02-92.28,P<0.001)were the factors influencing the disappearance of lesion 12 months after RFA.Conclusions PTC with calcification can be treated with ultrasound-guided RFA.In the case of calcification ratio ≤ 2/3,this therapy demonstrates the effect equivalent to that of no calcification.

  • Review Articles
    MAO Yi, ZHANG Mingbo
    Acta Academiae Medicinae Sinicae. 2023, 45(5): 853-858. https://doi.org/10.3881/j.issn.1000-503X.15401
    Abstract (1167) Download PDF (706) HTML (947)   Knowledge map   Save

    With the continuous advances in modern medical technology and equipment,minimally invasive surgery (MIS) is widely applied in clinical practice.Ultrasound (US) as a real-time,portable,and radiation-free medical imaging method can be used for the intraoperative guidance in MIS to ensure safe and effective surgery.However,the physical characteristics of conventional US fail to display some tissue structures of the human body due to the existence of gas and bone.US-based navigation can make up for the deficiencies by advanced imaging technologies including spatial orientation,image reconstruction,and multi-modality image fusion,being real-time,accurate,and radiation-free.Therefore,US-guided robots can achieve safe,effective,and minimally invasive operation in MIS.This paper reviews the studies of US-guided robots in MIS and prospects the development of this field.

  • Original Articles
    HU Min, CHEN Shiyu, YANG Xiaolong, LIN Tianfang, WANG Jiefeng, ZANG Zhenghua
    Acta Academiae Medicinae Sinicae. 2023, 45(3): 436-439. https://doi.org/10.3881/j.issn.1000-503X.15472

    Objective To investigate the clinical value of high-frequency ultrasound in the diagnosis of pronator teres syndrome (PTS). Methods The high-frequency ultrasound was employed to examine and measure the median nerve of the pronator teres muscle in 30 patients with PTS and 30 healthy volunteers (control group).The long-axis diameter (LA),short-axis diameter (SA) and cross-sectional area (CSA) of the median nerve were measured.The receiver operating characteristic curve of the median nerve ultrasonic measurement results was established,and the area under the curve (AUC) was calculated.The diagnostic efficiency of each index for PTS was compared with the surgical results as a reference. Results The PTS group showed larger LA[(5.02±0.50) mm vs.(3.89±0.41) mm;t=4.38,P=0.013],SA[(2.55±0.46) mm vs.(1.70±0.41) mm;t=5.19,P=0.009],and CSA[(11.13±3.72) mm2 vs.(6.88±2.68) mm2;t=8.42,P=0.008] of the median nerve than the control group.The AUC of CSA,SA,and LA was 94.3% (95%CI=0.912-0.972,Z=3.586,P=0.001),77.7% (95%CI=0.734-0.815,Z=2.855, P=0.006),and 78.8% (95%CI=0.752-0.821,Z=3.091,P=0.004),respectively.With 8.63 mm2 as the cutoff value,the sensitivity and specificity of CSA in diagnosing PTS were 93.3% and 90.0%,respectively. Conclusion High-frequency ultrasound is a practical method for diagnosing PTS,and the CSA of median nerve has a high diagnostic value.

  • Expert Forum
    YU Wei, ZHANG Zaizhu
    Acta Academiae Medicinae Sinicae. 2023, 45(2): 285-289. https://doi.org/10.3881/j.issn.1000-503X.15133
    Abstract (13012) Download PDF (6200) HTML (11745)   Knowledge map   Save
    CSCD(8)

    Age,a basic marker of the population,is an indispensable demographic characteristic in medicine.However,the grouping in medicine according to age have problems such as inconsistent grouping criteria and ambiguous definition of age-related terms.Therefore,this article reviews the age-based grouping criteria and the application of related terms in medicine.

  • Review Articles
    YANG Zhen, ZHANG Mingbo, LUO Yukun
    Acta Academiae Medicinae Sinicae. 2023, 45(2): 298-302. https://doi.org/10.3881/j.issn.1000-503X.14827
    Abstract (1258) Download PDF (471) HTML (807)   Knowledge map   Save
    CSCD(2)

    In real-time ultrasound,molecular targeted contrast agent is introduced into the blood circulation through peripheral intravenous injection to enhance the imaging signal of target lesions after binding to the corresponding intravascular receptors,which can realize early diagnosis,staging of diseases,assessment of treatment response,and targeted treatment.In addition,molecular targeted ultrasound contrast agents provide a platform for the delivery of drugs and genes via microbubbles,and nanoscale contrast agents can be infiltrated through vascular endothelium into the interstitial space of the lesion for imaging or treatment.The available studies of molecular targeted ultrasound contrast agents mainly focus on the preclinical trials.Some clinical trials have been conducted in humans and preliminarily confirm the safety and feasibility of targeted ultrasound contrast agents.The molecular targeted ultrasound contrast agents enjoy a broad prospect in clinical application.